If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamps
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need two 120 V/300 W GX-6.35 lamps.
During the operation, the lamp reaches temperatures of up to 600° C .
Procedure:
Step 1: Unscrew the screw on top of the housing.
Step 2: Open the housing.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Put the new 120 V/300 W GX-6.35 lamp into the lamp-socket.
Step 5: Replace the housing and tighten the screw.
Overhead rigging
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened housing!
DANGER TO LIFE!
14/32
00018469.DOC, Version 7.1