CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The
selected program will be restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
Battery Size (Ah)
NORMAL
20–160Ah
AGM
CEC-400
27–95Ah
RECOND
10 • EN
50018323A Manual, User Instruction TIME TO GO NA, Print file_007.indd 8
Explanation
Normal battery program
14.4V/4.3A. Use for WET, EFB, Ca/Ca, MF, GEL batteries and many AGM
batteries.
AGM battery program
14.7V/4.3A. Use for AGM batteries.
Recond program
15.8V/1.6A
Use to return energy to the empty WET, EFB and Ca/Ca batteries. Recond your
battery once per year and after deep dischare to maximise lifetime and capacity.
During this program the battery will first be charged with the Normal battery
program" and then reconditioned with the "Recond program".