check valve clearance
Regular valve clearance check and adjustment will improve performance and extend
engine life. This procedure cannot be done without partial engine disassembly and the
use of special tools. For this reason we recommend that you have an authorized dealer
check and adjust valve clearance at 250 hours or as recommended (see Maintenance
Schedule in the Maintenance section).
after each use
Water should not remain in the unit for long periods of time. Sediments or minerals
can deposit on pump parts and freeze pump action. Follow these procedures after
every use:
1. Shut off engine, turn off water supply, point gun in a safe direction, press red
button and squeeze trigger to relieve trapped pressure, and let engine cool.
warning The high pressure stream of water that this equipment produces
could cut through skin and its underlying tissues, resulting in serious
injury and possible amputation.
Spray gun traps high water pressure, even when engine is stopped and
water is disconnected, which could result in serious injury.
• Keep high pressure hose connected to pump and spray gun while system is
pressurized.
• ALWAYS point spray gun in safe direction, press red button and squeeze spray
gun trigger to release high pressure, every time you stop engine.
2. Disconnect hose from spray gun and high pressure outlet on pump. Drain
water from hose, spray gun, and nozzle extension. Use a rag to wipe off the
hose.
3. Empty pump of all pumped liquids by pulling recoil handle about six times. This
should remove most liquid in pump.
4. Store unit in a clean, dry area.
5. If storing for more than 30 days, see Long Term Storage.
warning Fuel and its vapors are extremely flammable and explosive which
could cause burns, fire or explosion resulting in death, serious
injury and/or property damage.
wHen storing FueL or eQuiPMent witH FueL in tank
• Store away from furnaces, stoves, water heaters, clothes dryers or other
appliances that have pilot light or other ignition source because they could ignite
fuel vapors.
winter storage
NOTICE You must protect your unit from freezing temperatures.
• Failure to do so will permanently damage your pump and render your unit
inoperable.
• Freeze damage is not covered under warranty.
to protect the unit from freezing temperatures:
1. Follow steps 1-3 in the previous section After Each Use.
2. Use pump saver to treat pump. This minimizes freeze damage and lubricates
pistons and seals.
3. If pump saver is not available, connect a 3 ft. (1 m) section of garden hose to
water inlet adapter. Pour RV-antifreeze (antifreeze without alcohol) into hose.
Pull recoil handle twice. Disconnect 3 ft. (1 m) hose.
4. Store unit in a clean, dry area.
Long term storage
If you do not plan to use the pressure washer for more than 30 days, you must prepare
the engine and pump for long term storage.
Protect Fuel system
Fuel additive:
Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum
deposits to form in the fuel system or on essential carburetor parts. To keep fuel
fresh, use Briggs & Stratton® Advanced Formula Fuel Treatment & Stabilizer, available
wherever Briggs & Stratton genuine service parts are sold.
For engines equipped with a FRESH START® fuel cap, use Briggs & Stratton FRESH
START® available in a drip concentrate cartridge.
There is no need to drain gasoline from the engine if a fuel stabilizer is added
according to instructions. Run the engine for 2 minutes to circulate the stabilizer
throughout the fuel system before storage.
If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained
into an approved container. Run the engine until it stops from lack of fuel. The use of a
fuel stabilizer in the storage container is recommended to maintain freshness.
change engine oil
While engine is still warm, drain oil from crankcase. Refill with recommended grade.
See Changing Engine Oil in Engine Maintenance.
Protecting the Pump
To protect the pump from damage caused by mineral deposits or freezing, use
PumpSaver to treat pump. This prevents freeze damage and lubricates pistons and
seals.
NOTICE PumpSaver is available as an optional accessory. It is not included with
the pressure washer. Contact the nearest authorized service center to purchase
PumpSaver.
NOTICE You must protect your unit from freezing temperatures.
• Failure to do so will permanently damage your pump and render your unit
inoperable.
• Freeze damage is not covered under warranty.
To use PumpSaver, make sure the pressure washer is turned off and disconnected
from supply water. Read and follow all instructions and warnings given on the
PumpSaver container.
other storage tips
1. DO NOT store fuel from one season to another unless it has been treated as
described in Protect Fuel System.
2. Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause
problems if it's used with this unit.
3. Cover unit with a suitable protective cover that does not retain moisture.
warning Storage covers could cause a fire resulting in death, serious
injury and/or property damage.
• DO NOT place a storage cover over a hot pressure washer.
• Let equipment cool for a sufficient time before placing the cover on the equipment.
4. Store unit in a clean and dry area.