Electrical supply

Before installing the oven have a qualified electrician verify
that your home is provided with adequate electrical service
and that the addition of the oven will not overload the branch
circuit on which it is to be installed.
A separate three-wire or four-wire single phase, 120/240 Volt,
60 Hz, or a 120/208 Volt, 60Hz branch circuit is required.
NOTE: For use with 120/208 v, 60 hz supply voltage, see
connecting to 208 volt circuit.
For hook-up of the oven you will need to have an approved
junction box installed where it will be easily reached through
the front of the cabinet where the oven will be located. The
oven has 3 feet of conduit.
Allow two to three feet of slack in the line so that the oven can
be moved if servicing is ever necessary.
DO NOT shorten the flexible conduit.
LOCATION OF RATING PLATE

Wiring requirements

When making the wire connections, use the entire length of the
conduit provided (3 feet). The conduit must not be cut.
Before making connections make sure the power is off and
read and observe the following:
1. A separate three-wire or four-wire, single phase,
120V/240V, 60 Hz or 120V/208V, 60 Hz branch circuit
is required for the oven.
2. The oven must be connected with Copper or Aluminum wire.
3. In the United States:
Wiring must conform to the National Electrical Code,
ANSI/NFPA No. 70 latest edition. You can obtain a copy
of the National Electrical Code by writing to: National
Fire Protection Association Batterymarch Park Quincy, MA
02269
6
In Canada:
Wiring must conform to Canadian Electrical Code C22.1-
latest edition. You can obtain a copy of the Canadian
Electrical Code by writing to: Canadian Standards
Association 178 Rexdale Boulevard Rexdale (Toronto),
Ontario, Canada M9W 1R3
4. Wire size (Copper or Aluminum wire) and connections must
be suitable for the rating of the appliance as per the National
Electrical Code requirements. The flexible armoured cable
extending from the oven should be connected directly to the
junction box.
5. The junction box should be located so as to allow as much
slack as possible between the junction box and the oven so
it can be moved if servicing is ever required.
6. A U.L. listed conduit connector must be provided at each
end of the power supply cable.
WARNING
ELECTRICAL SHOCK HAZARD
• The electrical power to the oven branch circuit must be
shut off while line connections are being made.
• Do not use an extension cord with this appliance.
• Electrical ground is required on this appliance. The free
end of the green wire (the ground wire) must be connected
to a suitable ground. This wire must remain grounded to
the oven.
• If cold water pipe is interrupted by plastic, non metallic
gaskets, union connections or other insulating materials,
DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the NEUTRAL or GROUNDING
circuit. A fuse in the NEUTRAL or GROUNDING circuit
could result in an electrical shock.
• Check with a qualified electrician if you are in doubt as to
whether the appliance is properly grounded.
• Failure to follow these instructions could result in serious
injury or death.
CAUTION
Do not repair or replace any part of the appliance unless
specifically recommended in the manual. All other servicing
should be done by a qualified technician. This may reduce
the risk of personal injury and damage to the oven.
Never modify or alter the construction of the appliance by
removing panels, wire covers, screws, or any other part of
the product.