Troubleshooting - Ferroli LATINA Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.5
Cleaning the air flow meter
The air flow meter (it measures the flow of combustion air) installed inside the inlet pipe requires periodical internal
cleaning every 3-4 months, using suitable equipment (blowing compressed air or suitable brushes).
5.6
Cleaning the ceramic surfaces (ceramic models)
The ceramic tiles are handicraft products and therefore may have minor surface imperfections such as tiny spots or
slight colour differences. It is advisable to use a soft dry cloth to clean the ceramic surfaces; the use of detergents
could highlight any flaws.
5.7
Cleaning the flue - flue connection
The flue connection must be cleaned at least once a year or whenever necessary depending on stove use and the
type of installation.
Cleaning requires the suction and removal of the residuals in all the vertical and horizontal sections as well as the
bends from the stove to the flue.
It is advisable to also clean the flue every year, to ensure correct and safe evacuation of fumes.
For any maintenance or end of season cleaning, COLA recommends contacting an authorised service centre, which
will also check the wear on the stove's internal components.
6
MAINTENANCE
6.1
Introduction
Operations on the internal parts of the stove must be carried out by qualified personnel. Contact the nearest
authorised service centre (removing the cladding, stove internal parts, electrical components – fig. 5.1 – 5.2 – 5.3)
Make sure the stove is unplugged and cold before carrying out any work on it.
7

TROUBLESHOOTING

7.1
Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm the shutdown procedure is automatically activated. Cancel the signalling by pressing button P4
and wait until the stove reaches OFF status. Eliminate the cause and restart the stove according to the normal
procedure described in this manual.
Listed below are the alarms that can appear on the control panel, with the causes and cures:
Signalling
Occurs in case of a power
AL 1
failure during the operation
POWER
phase
FAILURE
AL 2
Occurs in case of a fume
FUME
temperature detection probe
fault
PROBE
AL 3
Occurs if the probe detects a
high fume temperature
HOT FUMES
AL 4
Occurs when the fume
FAN FAIL
exhaust fan is faulty
ALARMS - MESSAGES
Fault
Electrical system power failure
in the stove installation room
- Probe fault
- The probe is disconnected
from the board
- Overheating due to use of
the stove for too long
- The tangential fan is faulty or
not powered
- Excessive pellet load
- The fume fan is blocked
- The speed control sensor is
faulty
- No power to the fume fan
Possible causes
44
Cures
- Turn the stove OFF by
pressing button P4 and repeat
the lighting procedure
- Other reinstatement
operations must be carried
out by a service centre
Reinstatement operations
must be carried out by a
service centre
- Wait for the stove to cool and
repeat the lighting procedure
- Other reinstatement
operations must be carried out
by a service centre
Reinstatement operations
must be carried out by a
service centre
LATINA

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

La22x07a

Tabla de contenido