CARE AND MAINTENANCE
TROUBLESHOOTING
If you have any questions regarding the product, please call customer service at 1-866-235-5112
PROBLEM
Unit will not turn on.
The high pressure
(HP) hose will
not connect/stay
connected to the
spray gun. Is this a
spray gun problem?
The unit is running
but there is no water
flow.
TROUBLESHOOTING
Why is water leaking
where the high
pressure hose
connects to the spray
gun?
I can't remove the
lance from the spray
gun. What should I
do?
16
CORRECTIVE ACTION
1. The GFCI module on the end of the power cord must be plugged directly into an outlet.
2. Do not use an extension cord.
3. With the GFCI Connected make sure the power switch is turned on.
Note: When power switch is turned on, the power washer will turn on by itself for 1-2
seconds and shut off. This is normal.
1. In most cases, the spray gun is not the problem. The problem is the rubber sleeve
covering the fitting at the end of the high pressure hose. It has likely slipped up toward
the metal tip. To fix: wiggle, twist and/or pull the rubber sleeve down until the entire tip
is visible plus an 1/8 in. of the metal fitting below the tip. Now try to insert the hose tip
into the spray gun. It should "click" into place and will not come out until the hose is
released by pushing in the lever on the underside of the gun. You may cut away the end
of the sleeve with a sharp knife if unable to move the sleeve down. Be careful not to cut
or puncture the hose.
2. Do not push in the release button when connecting the high pressure hose.
1. Check the water source. Unclog the nozzle on the lance. (See nozzle cleaning
instructions under "Cleaning nozzles".) Or take off the lance and just spray out of the
spray gun. This will indicate if the problem is with the lance.
2. Reconnect the QC Garden Hose Adapter to the clear quick connect.
1. Make sure there is an o-ring at the end of the metal tip of the high pressure hose. If
no o-ring is present, the connection between the hose and spray gun will leak. O-Ring
Kits are available online at www.arblueclean.com or call Customer Service at
1-866-235-5112 to place an order.
1. All lances and the detergent bottles are attached and removed from the extension
lance in the same manner. Insert the quick-release end of the lance/detergent bottle
into the extension lance. Press the extension lance and lance together (about a 1/8")
and turn clockwise. The lance will lock in place. Remove the lance by reversing this
procedure. Press the extension lance and lance together and turn counter clockwise.
The lance will slide out.
2. Or, hold the extension lance and lance in an upright position with the nozzle end on
the floor. Push the whole assembly straight down to loosen the connection, and then
follow the removal process again. You may also spray soapy water or a lubricant in the
area where the lance connects to the extension lance.