Positioning With Automatic, Angular, Flow Pack, Etc. Packaging Machine; Electrical Connections; Chapter 6. Machine Adjustment And Setting Up; Direction Of Rotation Check (Reserved To The Assistance Personel) - Minipack-Torre Tunnel 50 Twin Manual De Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Chapter 5. Machine installation

5.3. Positioning with automatic, angular, flow pack, etc. packaging machine

Position the "Tunnel 50 Twin" / "Tunnel 70" so that the conveyor belt of the tunnel is as close to the outfeed belt of the
"packaging machine" as possible.
The tunnel conveyor belt must be 1mm higher than that of "packaging machine", to keep packaged products from falling.
Position the tunnel so that the outfeed product from "packaging machine" is positioned at the centre of the tunnel
conveyor belt.

5.4. Electrical connections

Voltage (V): see data on plate
Frequency (Hz): see data on plate
Maximum absorbed power (W): see data on plate
Maximum absorbed current (A): see data on plate
Note: When contacting the Manufacturer, always indicate the model and the serial number
specified on the plate on the rear part of the machine.
OBSERVE HEALTH AND SAFETY REGULATIONS!
If the machine is not equipped with the power supply plug, use a plug that is suitable for the
voltage and amperage values described by the rating plate and that can comply with the rules in
force in the installation country.
GROUNDING OF THE UNIT IS OBLIGATORY!
Before making electrical connections, make sure the mains voltage matches the one on the
plate on machine rear and that the ground contact complies with the safety rules in force.
In case of doubts about the mains voltage, contact the local power supply company.
Insert the plug on the cable from machine electrical cabinet in a mains power supply socket that
can be reached easily by the operator.

Chapter 6. Machine adjustment and setting up

6.1. Direction of rotation check (reserved to the assistance personel)

Before starting machine operation check the correct direction of rotation
by following these instructions:
1.
Connect the power cord to a three phase plug plus earthing.
2.
Turn the main switch (1) into position 1.
3.
Press START button (5).
4.
Check that the rotation sense of the motor fan (M1) and (M2) shown in the picture
corresponds to the sense indicated by the arrow.
Note: The control of direction of rotation should be carried out each time you change
the electrical plug.
In case the rotating sense is directed counterclockwise, DISCONNECT THE
MACHINE and reverse two of the three phases of the feeding plug.