Declaration Of Compliance; Range Technical Data Table; Instructions For Installation; Installation - Lotus CF4-78ET Guia Para La Intalación E Instrucciones De Uso

Cocina con horno electrico para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part and with norm
2006/95/CE,
in force particularly concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENSIONS
MODELS
cm
CF4-78ET
80x70x90
CFQ4-78ET
80x70x90
CFC4-78ET
80x70x90
CF6-712ETV
120x70x90
120x70x90
CFQ6-712ETV
CF6-712ET
120x70x90
120x70x90
CFQ6-712ET
CFV4-78ET
80x70x90
CFVQ4-78ET
80x70x90
CFVC4-78ET
80x70x90
CFV6-712ETV
120x70x90
120x70x90
CFVQ6-712ETV
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
Disconnect the power supply.
Remove the bottom panel
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
GB
IT

DECLARATION OF COMPLIANCE

2004/108/CE
for the electric part. The installation must be done observing the norms

RANGE TECHNICAL DATA TABLE

POWER SUPPLY
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz
400V 3N 50/60 Hz

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

ELECTRIC CONNECTION

IE
CH
MAXIMUM
MAXIMUM
ABSORPTION
POWER kW
A
27,8
15,4
27,8
15,4
27
15
33
20,6
33
20,6
33
22,5
33
22,5
30,14
15,7
30,14
15,7
29,28
15,3
30,67
20,9
30,67
20,9
29
Emissivity
POWER SUPPLY
CABLE (Silicone)
dB(A)
/
5x4 mm²
/
5x4 mm²
/
5x4 mm²
/
5x6 mm²
/
5x6 mm²
/
5x6 mm²
/
5x6 mm²
<70
5x4 mm²
<70
5x4 mm²
<70
5x4 mm²
<70
5x4 mm²
<70
5x4 mm²

Publicidad

Tabla de contenido
loading

Tabla de contenido