Uline H-1619 Manual De Instrucciones página 8

Ocultar thumbs Ver también para H-1619:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

An operator may check the status of the machine by
running a self-test. If the procedure is carried out
properly, the INFO screen will display the location of the
problem(s).
To run the self-test, follow the procedure below:
1. Turn the turntable and carriage speed adjustment
knobs to maximum (clockwise) position.
2. Put a load on the turntable (about 3 feet tall).
3. While holding down the TURNTABLE JOG and
CARRIAGE JOG buttons, turn the main disconnect
switch ON.
4. Release the buttons after the screen shows "EE".
5. Push the START button. The machine will run the test,
which takes approximately 2 minutes.
6. The screen will display the alarm code. Refer to the
table below for code information.
PAGE 8 OF 33
SELf-TEST pROCEDURE
A1
F1
B1
G1
E1
C1
D1
DISpLAy
pOSSIBLE pROBLEM LOCATION(S)
A1
Film carriage Safety Bar
EMERGENCY STOP button
Electrical enclosure safety switch
B1
Film carriage max upper limit switch
C1
Film carriage max down limit switch
D1
Turntable count/home proximity switch
E1
BANDING push button
F1
START push button
G1
Package height photo sensor
A2
START light
B2
Turntable motor
C2
Carriage motor
A2
B2
C2
0913 IH-1619

Publicidad

Tabla de contenido
loading

Tabla de contenido