Description
2.5

Limitations on use

The thermal imaging cameras cannot see through glass or water.
Shiny and glossy surfaces (e. g. metal, glass) reflect thermal radiation
and can lead to loss of orientation if the user is not sufficiently trained
in using the camera.
2.6

Approvals

NOTICE
i
i
The thermal imaging cameras have different approval
combinations. The approvals for each camera are specified
on the handle.
All thermal imaging cameras comply with European Directive
2014/30/EU (electromagnetic compatibility).
The protection class of the thermal imaging cameras according to
IEC 60529 is IP67.
The thermal imaging cameras feature a class 2 laser pointer
according to IEC EN 60 825-1 and 21 CFR 1040.10.
2.6.1

Approval for explosion-hazard areas

The thermal imaging cameras for use in explosion-hazard areas
feature an intrinsically safe design according to the following
standards:
IEC 60079-0
IEC 60079-11
EN 60079-0
EN 60079-11
ANSI/ISA 12.12.01
CAN/CSA E60079-0
CAN/CSA E60079-11
38
UL 60079-0
UL 60079-11
They are classified as follows:
For Europe according to 2014/34/EU (see declarations of
conformity on Page 173 and Page 174): I M2 / II 2G, Ex ib I Mb /
Ex ib IIC T4 Gb
For Australia: Ex ib IIC T4 Gb
For the USA and Canada: Class I, Div. 2, Groups A, B, C, D,
Class I, Zone 1, Ex ib IIC T4
2.6.2

GOST approval

For information on cameras approved in Russia, see supplement
9031024.
2.7

Markings/Labeling

The startup screen displays the identification of the thermal imaging
camera (order number, serial number, and software version).
The order number, model name, and serial number can also be found
on a separate sheet enclosed in the packaging.
Order number and serial number are also indicated on the handle. The
year of manufacture is encrypted in the serial number. The year of
manufacture results from the third letter of the serial number: E = 2013,
F = 2014, H = 2015, J = 2016, K = 2017 etc. Example: Serial number
ARHH-0054: The third letter is H, which means the year of
manufacture is 2015.
Warning symbol on the thermal imaging camera:
Laser radiation! Do not look directly into the laser
beam. Do not point the laser at a person's head!
Always switch off the laser pointer when it is not used.
Dräger UCF 6000, UCF 7000, UCF 8000, UCF 9000

Publicidad