ASSEMBLY

Caster/Caster Foot Assembly

NOTE: Remove Powerhead Assembly
from Dust Drum prior to assembly of
Casters and Caster Feet.
1. Turn Dust Drum upside down on floor.
2. Place Caster Foot on floor. Insert the
stem of a Caster into socket of Caster
Foot.
3. Push on the Caster until the Caster ball
end snaps fully into the Socket and the
Caster swivel freely. Repeat for other
three Casters and Caster Feet.
4. Place Caster Foot with Caster over
post on bottom of Dust Drum and press
firmly in place, as shown.
5. Repeat for the other three Caster/
Caster Foot assemblies.
6. Turn the Dust Drum upright.
Post
Dust
Drum
Caster
Caster Stem
Caster Ball
Caster
Foot
Caster Foot
Caster Foot
Post Hole
Wet/Dry Vac Assembly
Attaching Powerhead Assembly
to Dust Drum
1. Place Powerhead Assembly on top of
Dust Drum with the Extended Lip of
the Lid aligned with the Inlet. Be sure
Powerhead Assembly is fully seated on
the Dust Drum.
Powerhead
Assembly
Extended
Lip
Inlet
Dust
Drum
2. Press in on the two Latches located
on either side of the Dust Drum until
they snap into place, securing the
Powerhead Assembly to the Dust Drum.
3. To remove the Powerhead Assembly,
pull out on the two Latches and lift
Powerhead Assembly from the Dust
Drum. Do not force the Latches to
rotate more than slightly outside Drum
flange.
Powerhead
Assembly
Drum
Latches
(1 on each
side)
Dust Drum