Cleaning And Maintenance; Technical Specifications - HQ-Power VDPLCW Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• DMX512 Chain with Termination
• DMX Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to "listen" to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDPLCW.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDPLCWs will "listen" to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will "listen" to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 6-channel VDPLCW, you will have to set the start address of the first VDPLCW to 1, the second
VDPLCW to 7 (1 + 6), the third to 13 (7 + 6) and so on.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts except the fuse.
8. Contact your dealer for spare parts if necessary.

7. Technical Specifications

Power Supply
Power Consumption
Fuse
LEDs
DMX512 Connection
Dimensions
Total Weight
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of
damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.hqpower.com.
The information in this manual is subject to change without prior notice.
VDPLCW
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
max. 230VAC / 50Hz
max. 15WW
1A, 250VAC (5 x 20mm) (order code FF1N)
96 x 5mm white LEDs
XLR 3-pin
2 x 3m
18kg
6
HQPOWER

Publicidad

Tabla de contenido
loading

Tabla de contenido