TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
NOTE: Meets the ENERGY STAR
with 120 W Max bulbs.
❒ Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control
to the TEST position.
ON-TIME
ON-TIME
10 5 1 TEST
10 5 1 TEST
MINUTES
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
Sensor
Least Sensitive
/
minute warm up period
1
2
guidelines when used
®
RANGE
RANGE
MIN
MAX
MIN
MAX
70 ft.
(21 m)
Maximum
Coverage Angle
Motion
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 240 Watt Maximum Tung-
Power Requirements . 120 VAC, 60 Hz
180°
Operating Modes . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
4
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
sten [Up to 120 Watt maximum
each lamp holder.]
MODE
598-1157-05