Technical Data - Leuze electronic IPS 208i Manual De Instrucciones

Ocultar thumbs Ver también para IPS 208i:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
HOST/Ethernet, M12 socket, D-coded
Pin No.
Designation
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE (functional
(M12
earth)
socket)
IP address
Factory settings for the network address of the IPS 208/248i and IPS 408i/448i
positioning sensors:
– IP address: 192.168.060.101
– Subnet mask: 255.255.255.0
IPS 258i/458i positioning sensors: automatic address assignment via DHCP
server
– IP address: 0.0.0.0

Technical data

NOTICE
Additional technical data and information on using the device can be
found in the operating instructions for the positioning sensor.
Operating voltage
Average power con-
sumption
Integrated LED illumina-
tion
Integrated feedback
LED
Number of pixels
Assignment
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Connection cable shield.
The shield of the connection cable is on the
thread of the M12 socket.
18 ... 30 V DC
PELV, Class 2 / SELV
8 W (without load on the switching output)
During strobed operation, a higher power can briefly be
consumed.
Infrared (850 nm)
Exempt group in acc. with EN 62471:2008
Green (525 nm)
1280 x 960 pixels
EN
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ips 248iIps 258iIps 408iIps 448iIps 458i

Tabla de contenido