For Your Safety
Working safely with this machine is
possible only when the operating
and safety information are read
completely and the instructions
contained
followed.
In addition, the Section Safety
Instructions for Pneumatic Tools
must be observed.
Before using for the first time, ask
for a practical demonstration.
Always wear goggles, protective gloves
and robust shoes when using the
appliance.
Wear ear protection!
Disconnect the air supply.
Disconnect the air supply when the machine is not
in use, before maintenance work and for the
changing of the tools.
Secure the workpiece.
Use clamping devices or a vice to hold the
workpiece in place. In this manner, it is held more
securely than with your hand and makes possible
the operation of the machine with both hands.
Protect yourself from electric shock.
Do not work on current conducting work pieces.
Keep your hands away from the cutting area of the
machine.
Clean away material debris regularly to prevent
injuries.
Be careful of flying debris whilst operating the
machine!
Be careful when cutting off excessive material as
this can fall on the operator, resulting in injuries.
Use the machine in a controlled manner. Careless
use can cause injury as well as breakage of the
cutting tool.
Bosch can assure flawless functioning of the
machine only when original accessories are used.
therein
are
strictly
Air Supply
The supplied air must be free of foreign material and
humidity
to
protect
contamination and rust.
The use of a pressurised air maintenance unit is
necessary.
All fittings, connecting lines and hoses must be
dimensioned for the required air pressure and volume.
Avoid restrictions in the air supply resulting from, e.g.,
pinching, kinking or stretching!
In case of doubt, measure the pressure with an
pressure gauge at the air inlet with the unit switched
on.
Maintenance Unit
The maintenance unit ensures fault-free functioning of
pneumatic tools.
It consists of three major components:
–
Filter with water separator,
–
Pressure reduction valve with pressure gauge,
–
Mist oiler.
Lubricant in the mist oiler: Motor oil SAE 10/SAE 20.
Do not use paraffin or diesel oil.
Adjust the mist oiler so that a thin film of oil collects on
the air outlet.
Observe the operating instructions of the maintenance
unit.
Putting into Operation
The unit operates optimally with a pressure of 6.3 bar
(90 psi) measured at the air inlet with the unit running.
Switching On / Off
Type 0 697 651 102 Locking switch
Switching on:
Push the on/off switch 1 to the front.
Switching off:
Pull the on/off switch 1 to the rear.
Type 0 607 561 106 Deadman's switch
Switching on:
Push the on/off switch 1 to the front.
Switching off:
Release the on-off switch 1.
Type 0 607 561 113 Lever switch
Switching on:
Press the lever switch 10.
Switching off:
Release the lever switch 10.
the
unit
from
damage,