Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

horizontal laser line will be directed to the wall. Switch on
the power. The instrument starts to self-level. Mark point A on
the wall to show the contact of laser beam with the wall. Turn the
instrument by 90° and mark points В, С, D on the wall. Measure
distance "h" between the highest and lowest points (these are A
and D points in the picture). If "h"is ≤ 6 mm, the measurement
accuracy is good. If "h" exceeds 6 mm, apply service center.
To check plumb
Choose a wall and set laser 5 m away from the wall. Hang
a plumb with the length 2.5 m on the wall. Turn on the
laser and make the vertical laser line meet the point of the
plumb. The accuracy of the line is in the range if the ver-
tical line doesn't exceed (up or down) the accuracy that is
shown in the specifications (±3 mm/10 m). If the accuracy
isn't corresponding with claimed accuracy, contact the au-
thorized service center.
Note: Because of construction of laser emitter laser beam
may be unhomogeneous and has different intensity of
brightness along the perimeter in different light condi-
tions. Unhomogeneous of laser beam: laser patch of light
but the center of laser beam is identified. Different laser
beam brightness: difference of intensity is up to 50%.

Care and cleaning

Please handle measuring instrument with care. Clean with
soft cloth only after any use. If necessary damp cloth with
some water. If instrument is wet clean and dry it carefully.
Pack it up only if it is perfectly dry. Transport in original con-
tainer/case only.
Note: During transport On/Off compensator lock (3) must be
set to position "OFF". Disregard may lead to damage of com-
pensator.
Specific reasons for erroneous measuring results
Measurements through glass or plastic windows;
Dirty laser emitting window;
After instrument has been dropped or hit. Please check
the accuracy.
Large fluctuation of temperature: if instrument will
beused in cold areas after it has been stored in warm
areas (or the other way round) please wait some min-
utes before carrying out measurements.
5

Publicidad

loading