All manuals and user guides at all-guides.com
PROBLEM
Prolonged excessive use of
Compressor is
not supplying
air.
enough air to
Compressor is not large
operate
accessories.
enough for air requirement.
Hole in hose.
Air leaks.
Motor will not
Fuse blown, circuit breaker
run.
tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
D29728
D29728
CAUSE
Decrease amount of air
usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Tighten any exposed fittings.
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse or
circuit breaker with higher
rating than that specified for
your particular branch circuit.
Check for proper fuse. You
should use a time delay fuse.
Check for low voltage
problem.
Check the extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Check the extension cord.
Check wiring connection
inside terminal box.
Have checked by a Trained
Service Technician.
18- ENG