Put the clamping socket (3) with the 3 clamping jaws (4) and the assembly pusher (5) into
their position. Make sure that all is well and tightly assembled.
:
■
Assemble the front socket (2) and the mouthpiece (1) back to the device:
7. TROUBLESHOOTING
Defect
Riveting mandrel does
not brake
Clamping jaws are sliding
on the mandrel
Mandrel cannot be
positioned into the
mouthpiece
Possible causes
1.3-pcs set of clamping
jaws is worn out or damaged clamping jaws
2.insuffi cient amount of
hydraulic oil in the device
3.air supply with insuffi cient
pressure
1.3-pcs set of clamping
jaws is worn out
2. metallic chips between
the clamping jaws
3. pusher spring too weak
1.selected mouthpiece
size is wrong
2. clamping jaws are stuck,
rest of mandrel is
not released
Solutions
1.exchange 3-pcs set of
2. refi ll hydraulic oil
3. increase the pressure of
the supplied compressed air
within the specifi ed range
1.exchange 3-pcs set of
clamping jaws
2. clean the clamping jaws
3. exchange pusher spring
1.use correct mouthpiece
size
2. remove residues of
mandrel by disassembling of
the front socket and the pillar
terminal