Turn or replace blunt indexable inserts or those with
worn off coating in good time. Blunt indexable inserts
increase the risk of the machine jamming and breaking
out.
Do not use the power tool without the guide plate.
Further safety warnings
Use ear protection during operation.
Indexable inserts, indexable-insert holder, workpiece
and chippings can be hot after working. Wear protec-
tive gloves.
Use only sharp, undamaged indexable inserts.
Keep your hands away from the milling area and the
application tools.
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Use a stationary extraction system and frequently blow
out the ventilation slots. When working metal under
extreme operating conditions, it is possible for conduc-
tive dust to settle in the interior of the power tool. The
total insulation of the power tool can be impaired.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Do not work materials containing magnesium. Danger
of fire.
Do not work CFP (carbon-fiber-reinforced polymer) and
materials containing asbestos. These materials are con-
sidered carcinogenic.
Replace a damaged or cracked auxiliary handle. Do not
operate the power tool with a defective auxiliary han-
dle.
Use and handling of the battery (battery pack).
To avoid hazardous situations such as burns, fire,
explosion, skin injuries, and other injuries when han-
dling the battery, observe the following instructions:
Batteries must not be disassembled, opened or reduced
in size. Do not subject batteries to mechanical impact
or shock. Hazardous vapours and fluid can escape in
case of damage and improper use of the battery. The
vapours can irritate the respiratory system. Liquid
ejected from the battery may cause skin irritations or
burns.
When battery fluid from a damaged battery has come
into contact with objects close by, check the respective
components, clean them or replace them as required.
Keep the battery away from heat and fire. Do not store
the battery in direct sunlight.
Do not remove the battery from its original packaging
until it is going to be used.
Before any work on the machine itself, remove the bat-
tery from the power tool. If the power tool accidentally
starts, there is danger of injury.
Remove the battery only when the power tool is
switched off.
Keep the battery away from children.
Keep the battery clean and protect it against moisture
and water. Clean contaminated battery terminals and
power tool connections with a dry, clean cloth.
Charge the batteries only with battery chargers recom-
mended by the manufacturer. A charger that is suitable
one type of battery pack may create a risk of fire when
used with another battery pack.
Keep the battery not being used away from paper clips,
coins, keys, nails, screws or other small metal objects,
that can make a connection from one terminal to
another. Shorting the battery terminals together may
cause burns or a fire.
Remove the power tool's battery during transport and
storage.
Use only intact original FEIN batteries that are intended
for your power tool. When working with and charging
incorrect, damaged, repaired or reconditioned batter-
ies, imitations or other brands, there is danger of fire
and/or explosion.
Follow the safety warnings in the operating instructions
of the battery charger.
Hand/arm vibrations
The vibration emission level given in this information
sheet has been measured in accordance with a stand-
ardised test given in EN 62841 and may be used to
compare one tool with another. It may be used for a
preliminary assessment of exposure.
The declared vibration emission level represents the
main applications of the tool. However, if the tool is
used for different applications, with different accesso-
ries or poorly maintained, the vibration emission may
differ. This may significantly increase the exposure level
over the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool
is switched off or when it is running but not actually
doing the job. This may significantly reduce the expo-
sure level over the total working period.
Identify additional safety measures to protect the oper-
ator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organi-
sation of work patterns.
Emission values for vibration
Determined with a 45° bevel.
Material being worked: S235JR, material thickness:
30 mm
Work procedure
1. workstep (c = 3 mm)
2. workstep (c = 5 mm)
K
* This measured value depends on the material and application
and can therefore also be exceeded.
en
29
Weighted
acceleration*
2
4.0 m/s
2
4.6 m/s
2
1.5 m/s