Troubleshooting - Elinchrom Ranger Quadra RX AS Manual De Instrucciones

Ocultar thumbs Ver también para Ranger Quadra RX AS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Troubleshooting

Unit does not switch ON
• Check if the ATO 20 A fuse is fitted in the Battery Box, exchange if the fuse is faulty.
• Check if the Battery Box is correctly attached.
Unit controls do not respond and cannot be switched off
• Disconnect all Flashhead cables.
• Disconnect the Battery Box.
• Disconnect the RQ Charger, if connected.
• Refit the Battery Box and switch the unit ON.
• If the unit shows this fault again, please contact your Elinchrom Service Centre.
The display flashes, no flash can be released
• Switch the unit OFF.
• Check if all Flashhead cables are correctly fitted.
• Check eventually another RQ Flashhead or flash cable.
• If the unit continues to show this fault, please contact your Elinchrom Service Centre.
The display shows:
• Switch the unit OFF and wait 5 minutes.
E1
• Switch the unit ON again.
• If the unit shows this fault again, please contact your Elinchrom Service Centre.
• The unit is overheated due to workload or high ambient temperature. Avoid direct sunlight.
• Switch the unit OFF and allow to cool down for approximately 15 minutes (depending on
E2
the ambient temperature). Switch ON again .
• If the unit shows "Er 2 again, please contact your Elinchrom Service Centre.
• Indicates an internal fault in the discharge circuit; "Auto Dump Function" .
• Switch the unit OFF and ON again.
E3
• Release a „Test Flash" to check the charge circuitry.
• This fault should be controlled at your Elinchrom Service Centre.
• Indicates an internal fault in the charge circuit.
• Switch the unit OFF.
E4
• Ensure the Battery Box is correctly attached to the unit and fuse ATO 20 is fitted.
• If the unit shows this fault again, please contact your Elinchrom Service Centre.
The unit shuts down shortly after switching on, even though the Battery is fully charged
• Check if the ATO 20 A fuse is placed in the Battery Box, exchange if the fuse is faulty.
• Check if the Battery Box is correctly fitted.
• Maybe the Battery is faulty, try another Battery Box.
• Check the Ranger Quadra Charger. The GREEN, RED or YELLOW LED should be active if the RQ
Charger is connected to the Battery and the mains.
• In case no LED light up replace, the RQ Charger and recharge the Battery Box again.
• If the unit shows this fault again, please contact your Elinchrom Service Centre.
EN
17

Publicidad

Tabla de contenido
loading

Tabla de contenido