Perform the following operations before starting
the unit:
- Remove the refill neck cap.
- Remove the sealing cap from the refill neck, levering by
means of a tool on the edge of the cap.
- Fill the tank with cooling liquid if necessary.
- Keep apart the sealing cap for future transport of the unit.
- Connect the red hose of the torch to the appropriate inlet
quick connector (3) (red colour - symbol
- Connect the blue hose of the torch to the appropriate outlet
quick connector (4) (blue colour - symbol
Filling or topping up of the tank must be per-
formed with cooling liquid, code 18.91.001.

3 SYSTEM PRESENTATION

3.1 Front panel

1
Cooling liquid outlet connector
To supply low temperature liquid into the torch cooling
circuit.
2
Cooling liquid inlet connector
To return the liquid that has been heated by the torch
into the cooling circuit inside the WU.
3
7 segment display
Allows display of the general parameters of the WU
during start-up, its correct operation and the internal
temperature of the cooling fluid.
Cooling unit disabled.
4
Cooling unit test

4 MAINTENANCE

Any maintenance operation must be performed by qualified
personnel only.
When the equipment is working, all the access and operating
doors and covers must be closed and locked.
Unauthorized changes to the system are strictly forbidden.
Prevent conductive dust from accumulating near the louvers
and over them.
- Check the quantity of liquid in the tank (2/3 water and 1/3
antifreeze liquid).
- Clean the unit inside by means of low-
pressure compressed air and soft bristle brushes.
).
- Check the electrical connections and all the connection
cables.
).
- Check the condition of the electric pump.
- Check the state of the hose connections.
Every six months, change the cooling liquid and wash out the
hoses and tank with water. Change the liquid in cases, where it
should boil, since it would loose its protective properties.
Failure to carry out the above maintenance will invalidate all
warranties and exempt the manufacturer from all liability.
Routine maintenance must be carried out on the
system according to the manufacturer's instruc-
tions.
Disconnect the power supply before every
operation!
Periodically check the cooling liquid level in the
tank. If the tank is completely empty and/or there
is air in the cooling circuit, this may cause mal-
functions of the pump.
Filling or topping up of the tank with cooling
liquid must be performed with the power source
and WU assembled and positioned on a horizon-
tal surface.
Filling or topping up of the tank must be per-
formed with cooling liquid, code 18.91.001.
The equipment must not be used without cooling
liquid.
Do not use conductive cooling liquids.