Temperature key:
1. Press the temperature key, activate the button / key to adjust the temperature, the light
in the middle of the temperature key is highlighted, the temperature content is displayed by
a three-digit digital tube, the first two bits show the temperature, and the last one displays
"℃" with the "point" of the digital tube.
2. The default temperature is 24 ℃. Set the temperature by clicking the button / key, and
automatically confirm after 5 seconds of no operation or directly click the temperature key
to confirm (temperature setting range 7Mel 35 ℃).
3. In the power-on state, press the temperature key for 5 seconds, and the Celsius mode
(point + c) is converted to Fahrenheit mode (when the point + F); machine is in Fahrenheit
mode, press the temperature key for 5 seconds to switch back to Fahrenheit mode.
4. In Fahrenheit mode, the default temperature is 75 °F and the setting range is 45 °F / 95
°F.
5. The Celsius and Fahrenheit modes have a memory function, and you can still remem-
ber the last pattern after a complete power outage.
Add and subtract keys▲/▼:
1. When there is no gear setting, timing setting and temperature setting, the two corre-
sponding lights are low and there is no response by pressing this key.
2. When making gear or timing setting or temperature setting, the two keys are active and
the indicator lights are highlighted.
3. Before setting the temperature, you must press the temperature key.
Dumping function:
1. When the angle between the machine dumping and the horizontal position is less than
35 ±5 degrees, the digital tube flashes and prompts "Eo", and all outputs are closed.
2.When the angle between the machine centralization and the horizontal position is more
than 50 ±5 degrees, the working state before dumping will be restored.
Anti-frost function:
1.In the standby state, the mid-range heating is automatically turned on when the probe
temperature is lower than 5 ℃ (41 °F), and when the probe temperature is higher than 7
℃ (45 °F), the heating is stopped and returned to the standby state.
2.When the frost protection function is turned on, the power LED highlights and flashes at
a frequency of 2 seconds per time, and the digital tube shows the current temperature
(degrees Celsius or Fahrenheit).
Supplementary explanation.
1.The machine in the working state has no operation after working 3min, and automatically
enters the screen flameout state (the power light is low and the rest is off); in the flameout
state, press any button to wake up the body.
2. Sensor short circuit, flashing prompt "EH"; sensor open circuit, flasing prompt "EL",
need to be repaired by power outage.
3.The product can be configured with infrared remote control function, and the remote
control button function corresponds to the control board button function one by one.