Mounting procedure
• Switch OFF power supply (Fig. 4.1 )
• Mark drill holes (Fig. 5.1)
• Drill holes and insert wall plugs (Fig. 5.2 )
• Installation with concealed power supply lead (Fig. 5.3 )
• Installation with surface-mounted power supply lead
(Fig. 5.4 )
• Connect conductors (Fig. 5.5 )
• Switch ON power supply (Fig. 5.7 )
• Make settings (Fig. 5.6 )
– Settings ➔ "6. Function"
• Fit shade (Fig. 5.7 )
6. Function
Factory settings:
Time setting:
Reach setting:
Twilight level:
Basic light level:
The sensor-switched light can be put into service after
mounting the enclosure and connecting to the mains
power supply. When putting into operation manually at the
mains switch, the light will switch OFF after 10 seconds
for the calibration phase and is then activated for sensor
mode. It is not necessary to operate the mains switch a
second time.
Function - control dials ( Fig. 6.1 )
Time setting ( stay-ON time ) ( Fig. 6.1/F )
The light's ON time can be set to any period from approx.
5 seconds to a maximum of 15 minutes. Any movement
detected before this time elapses will restart the timer.
Note:
After the light switches OFF, it takes approx. 1 second
before it is able to start detecting movement again. The
light will only switch ON in response to movement once this
period has elapsed.
The shortest time setting is recommended when adjusting
the detection zone and performing the functional test.
Reach setting ( sensitivity ) ( Fig. 6.1/G )
Reach is the term used to describe the diameter of the
more or less circular detection zone produced on the
ground for a mounting height of 2.5 m.
– Control dial set to maximum = max. reach
– Control dial set to minimum = min. reach
Twilight setting ( response threshold ) ( Fig. 6.1/F )
The light's chosen response threshold can be infinitely
varied from approximately 2 to 2000 lux.
– Control dial set to
= daylight mode ( depending on
ambient brightness )
– Control dial set to
= twilight mode ( approx. 2 lux )
The control dial must be turned to
the detection zone and performing the functional test in
daylight.
5 seconds
M1: max. 8 m
2000 lux
OFF
when adjusting
Basic light level function ( Fig. 6.1/E )
The basic light level function provides illumination at
approx. 10% light output when the brightness setting is
reached.
Movement in the detection zone switches the light ON at
100% brightness for the time selected.
Light switches OFF completely after the selected time has
elapsed. If the brightness setting has not yet been reached,
basic light is switched back ON again.
– Control dial set to
– Control dial set to 0
Basic light is ON when the level of light falls below the
brightness threshold. Basic light is always ON when
daylight mode is activated.
Basic light switches OFF every hour to measure ambient
brightness. Basic light switches back ON again after a
short period.
Manual override function
If an optional mains switch is installed in the mains supply
lead, the following functions are available in addition to
simply switching light ON and OFF:
Manual override ( Fig. 6.2)
1 ) Activate manual override:
Switch OFF and ON twice. The light is set to manual
override for 4 hours. Then it returns automatically to
sensor mode.
2 ) Deactivate manual override:
Switch OFF and ON once. Light goes out or switches
to sensor operation.
Important:
Switching must take place within 0.2 to 1 second.
7. Disposal
Electrical and electronic equipment, accessories and pack-
aging must be recycled in an environmentally compatible
manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only
Under the current European Directive on Waste Electri-
cal and Electronic Equipment and its implementation in
national law, electrical and electronic equipment no longer
suitable for use must be collected separately and recycled
in an environmentally compatible manner.
Important note: the control gear cannot be replaced.
- 11 -
= basic light level ON
= basic light level OFF