6.2.6 Attach the cover frame

Tighten the screws carefully so that the cover frame is not damaged.
The supplied cylindrical screws are suitable for the usual installation condi-
tions. If the length of the screws for attaching the cover frame is not sui-
table, you can replace these by standard commercial screws of the same
type. Determine the required screw length as shown in Fig. 9 on page 6 (x
= screw length).
➤ Attach the cover frame (see fig. 4 on page 4, Pos. 4) with the four cy-
lindrical screws + washers M7 (see fig. 4 on page 4, Pos. 6) to the
system.
6.3

Configuration of system software

Before you first start up the system, adapt the controls according to the in-
stallation conditions. This must be done by the person installing the sys-
tem.
In configuration mode, the following system software parameters must be
set on the control panel (see fig. 10 on page 6):
Menu
Parameter
level
1
Set temperature The system starts with the tempe-
2
Low-voltage
cut-off
3
Operating mode The system starts with the opera-
4
Default
settings
The configuration mode can also be called if the undervoltage protection
has switched off the system and there is only residual voltage.

6.3.1 Start and end configuration mode

The adjustable parameters can be altered in edit mode:
➤ With the system switched off, press the ON/OFF button (see fig. 10 on
page 6, Pos. 1) and hold it down for 2-4 seconds.
30
All manuals and user guides at all-guides.com
Meaning
rature defined here.
The battery monitor switches the
system off at the defined voltage.
ting mode defined here.
The parameters 1-3 can be retur-
ned to the default settings.
CoolAir
Default
setting
20 °C
ID number
4 = 23.5
Volt
0 =
Automatic
mode
--