VIDEOPORTERO 2 HILOS | 2-WIRE VIDEO DOOR ENTRY SYSTEMS | VIDÉO-PORTIER 2 FILS
ASSIGNING PUSH-BUTTONS TO EACH BUILDINGS (only for external panel)
1. Description
In compounds with several inner buildings, before being able to make a call from the external
point of entry to the different dwellings, it is necessary to tell the system which pushbuttons
correspond to each of the inner buildings. Pushbuttons must be assigned to the different
buildings from the entrance panel of the external point of entry.
This information is stored in the non-flash memory of the main module of the external panel.
If the main module of the external panel is subsequently replaced, do not forget to re-assign
pushbuttons to buildings.
For compounds with several external points of entry, pushbuttons must be assigned to
buildings at each of the points of entry.
2. Paso previo: Orden de asignación
The pushbutton panels are formed of compartments of one or two rows of pushbuttons. Each
compartment is joined to the next by connectors, except for the last compartment which is
joined to the main module.
When assigning pushbuttons to the different buildings, if is necessary to begin with the
bottom row of the first compartment of the panel and to finish with the top row of the
compartment which is connected to the main module.
By doing this, the right pushbutton of the first compartment will be assigned to the first
dwelling of building number 1, while the left pushbuffon of the last compartment will be
assigned fo the last dwelling of the last building of the compound (i.e. the building with
the highest number).
An example is shown below.
3. Example of assigning pushbuttons to buildings: Compound of 24 dwellings,
distributed in 3 buildings of 8 dwellings each
EXTERNAL ENTRANCE PANEL CONSISTING OF 1 PANEL OF 24 PUSHBUTTONS
A
Detail: joining of pushbutton compartments
66
Assigning Pushbuttons
Building 3
Flats
Building 2
Flats
Building 1
Flats
8
7
5
6
4
3
2
1
8
7
5
6
4
3
2
1
8
7
5
6
4
3
2
1