2a. Plug the yellow mini plugs of the 3IREDB and/or the 3IREDH into one of the yellow
labelled "EMITTERS" jacks of the IRHUB4 Connecting Hub.
2b. Plug the IRQC cable into one of the yellow labelled "EMITTERS" jacks of the IRHUB4, and
the other side into the 3.5mm mono IR input of your AVR. IRED Mono TS 3.5mm pin
configuration: tip is IR Data, sleeve is Ground. (Please check the manual of the device for
matching PIN Configuration).
3. Position the IR Link Pro Mini IR Receiver in a location outside of the equipment cabinet or
closet that will have a straight line-of-sight view of your Hand Held Remote(s). The Receiver
can be fixed to the surface by using the double side tape pad.
4. Plug the red mini-plug of the IR Link Pro Mini IR Receiver into the red labelled "IR RCVR"
jack on the IRHUB4 Connecting Hub.
5. Plug the 12VDC Power Supply into an unswitched 230V~50Hz outlet.
Note: It is important that you use an unswitched AC outlet so that the IR system is always
active for system power ON commands.
6. Plug the 2.1mm "C" plug of the Power Supply Adapter into the "+12VDC" jack on the
IRHUB4 Connecting Hub.
Status
The Ebode IR link Pro Mini has a unique feature called "STATUS". It can show you if a hidden
out of sight source (e.g. amplifier) is powered ON or OFF with an Amber coloured LED build-
in the front of the IR Receiver. Once you apply power (5-24VDC) to JP2 on the Ebode
IRHUB4 from your source (e.g. amplifier), it will tell you if the source is powered or not. Most
amplifier also have 12v trigger outputs and additional switched power outlets that can be
connected to JP2 on the Ebode IRHUB4 (see figure 3). The input voltage range is 5–24VDC &
5–12VAC. Socket 2.1mm, pin configuration: centre/red is ST/+VDC, sleeve/black is GND
(PSU not included).
On the top of the IRHUB4 cabinet there is a cut out for jumper placement. The default
position of the jumper is the parking position JP1. You have 3 different status LED response
positions:
21-2-2014