VTSA−...−ASI−4E4A−Z
AS−Interface bus connection
Voltage range (protected against
incorrect polarity)
Residual ripple
Max. current consumption:
Electronics (basic load)
max. sum current for inputs
max. sum current for outputs
(valves incl. LED)
Max. permitted complete I/O current
Additional supply (load voltage)
Rated value (protected against
incorrect polarity)
Residual ripple
Current consumption
Valves (see Pneumatics manual
P.BE−VTSA−...)
Current consumption per solenoid
coil (with LED) at 24 V
1)
All 4 solenoid coils ON"
Festo VTSA−ASI−...−4E4A−Z 0802NH English
1)
26.5
31.6 V DC
˚20 mVpp
< 25 mA
350 mA
with additional power
supply: 350 mA
without additional power
supply: 500 mA
21.6
26.4 V DC
(24 V DC ±10 %)
˚4 Vpp
see valves
Watchdog function active
after approx. 40
3/2−way
5/2 and
valves
3/2−way valves
60 mA
72 mA
100 ms