6.1 Replacing the supply cord
DANGER
Risk of injury! Risk of electric shock.
▶ The product may be serviced and repaired only by authorized, trained
personnel! This personnel must be specially informed of any possible
hazards.
If it is damaged, the supply cord has to be replaced.
Comply with the country-specific regulations for electrical safety.
1. Unplug the charger's supply cord from the power outlet.
2. Pull the rubberized foot out of the cover and remove the securing screw
exposed by removal of the rubberized foot.
Materials
Torx
screwdriver T10
®
3. Flip the cover open.
4. Take a photo or draw a sketch so that you will be able to recall the
routing and conductor-to-terminal assignment of the supply cord.
5. Carefully depress one of the terminal clips with a flat screwdriver to
release the conductor. Disengage the conductor from the terminal clip.
Repeat this step for the second conductor and then remove the faulty
power cord.
6. Install the new supply cord.
screwdriver and insert the end of the conductor into the terminal clip.
Release the terminal clip and check that the conductor is secure in the
terminal clip. Repeat this step for the second conductor.
Materials
Supply cord C 6­22
2289588 (EU, 220­240V)
2289589 (US, 110­120V)
2289910 (GB, 220­240V)
2300624 (GB, 100­120V)
2289911 (KR, 220­240V)
2289912 (RU, 220­240V)
2289914 (JP, 100­120V)
2289915 (AUS 220­240V)
2289916 (TW, 100­120V)
2300625 (CH, 220­240V)
Select the supply cord of a type suitable for use with this charger
from this table or contact Hilti Service.