POS. DESCRIPTION
1
Red plastic washer
2
White plastic washer
3
Blue plastic washer
4
Relief/non return valve
5
Hose clamp
6
Discharge pipe
7 A
Element gasket
from S/N 100.000
7 B
Element gasket
from S/N 200.000
8A
Electric element
1200W 220V
8B
Electric element
500W 220V
8C
Electric element
1200W 110V
8D
Electric element
600W 110V
9
Bi-Thermostat
10
Power supply cable
11A
B3 resistor cover 220V
11B
B3 resistor cover 110V
12
Nut M4 stainless steel
13
Ground cable terminal
14
Washer
15
Screw 2,9 x 19
16A
Tank mounting
B3 300
16B
Tank mounting
B3 360
16C
Tank mounting
B3 400
17A
Metal bracket
B3 300
17B
Metal bracket
B3 400
18
Screw M8 stainless steel
19
Washer Ø 8 stainless steel
20
Nut M8 stainless steel
21
Cable clamp
22
Screw 2,9 x 16
BOILER B3 15-80 - REV004B
All manuals and user guides at all-guides.com
CODE
PECRBLRS0000
PECRBLBNC000
PECRBLBL0000
MNVALS12S68P
• shut down power supply.
PBF25100W000
• Remove the protection cover (11) in order to reach
PVTBGM10NT00
the thermostat (9).
• Push the reset button on the double thermostat (fi g. 4).
PGGRES000000
• Replace on the protection cover (11).
• Switch on power supply.
PGRM43500000
EVR12220N000
EVR05220N000
MAINTENANCE
EVR12110N000
EVR06110N000
F
EVT15S000000
ECC30150G000
PECRB220B300
PECRB110B300
The overpressure release device must be activated regu-
MBD04MXEN000
larly to remove calcium deposits and to ensure that it is not
EJCY04000000
blocked.
MBR04X000000
MBV02919AXCC
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
MBFPNXB3300
them in case they are worn or corroded.
MBFPNXB3360
Also periodically check the electrical system working order.
MBFPNXB3400
MMSTXB300000
MMSTBL400DR1
MBV0830MXE00
MBR08X000000
MBD08MXEN000
PPBLB3000000
MBV02916AXCC
MAINTENANCE
WARNING: Quick
®
nautic water heaters are provided
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
WARNING: if the high temperature safety system
switches on repeatedly, call Quick
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (4). This is to avoid serious damage caused
by freezing.
GB
®