Combustion Head Adjustment; Air Intake Adjustment - Lamborghini Caloreclima ECO 50/2 Manual Para La Instalación Y El Mantenimiento

Quemadores a gas con dos llamas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

COMBUSTION HEAD ADJUSTMENT

Adjusting screw A modifies the position of the line choke/deflector with regards to the flow nozzle, thereby
varying the opening of the air intake.

AIR INTAKE ADJUSTMENT

The motor reducer controls the air intake valve. Adjustment of the open/close position of the 1° flame / max.
opening is controlled by turning the cam anti-clockwise to open the butterfly valve and clockwise to close.
Blue cam
totally closed
Orange cam
air control 1° flame
Red cam
air control 2° flame
Black cam
Permits opening of the
electromagnetic valve of
the 2° flame
Servocontrol type SQN 70...
All manuals and user guides at all-guides.com
A
ECO 50/2
ECO 70/2
Red
Blue
Orange
Black
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eco 70/2

Tabla de contenido