4-WIRE SERVICE CORD OR CONDUIT INSTALLATION
(MOBILE HOMES OR AS REQUIRED BY CODES)
5. The copper ground strap connected between the
neutral (middle) post of the main terminal block and the
chassis MUST be cut off as shown in figure 8. Save the
green ground screw to attach the ground from the 4
wire cord. Only a 4 wire cord or conduit should be
used.
6. The ground wire from the service cord or conduit must
connect to the range chassis using the green ground
screw.
CONVERSION FROM 3-WIRE TO 4-WIRE SERVICE
(Free-standing Model With 3-Wire Service Cord Attached)
Disconnect range from power. Remove the access cover
on back of range and remove the 3-wire service cord from
the main terminal block. Follow instructions as outlined in
figure 8 to connect the 4-wire service cord.
All manuals and user guides at all-guides.com
FIGURE 8
ACCEPTABLE 4-WIRE PLUG INSTALLATION
-8-
7. The white wire of the service cord or conduit must
connect to the neutral (middle) post of the main
terminal block. The other two wires of the service cord
or conduit connect to the red and black posts of the
main terminal block, respectively.
8. An appropriate strain relief for service cord or conduit
must be attached to the conduit plate.
NOTE: Cord replacement - ONLY a power supply cord
rated at 240 volts minimum, 40 amperes or 50 amperes
power supply cord that is marked for use with nominal
1 3/8² (34.93 mm) diameter connection opening, with
closed loop terminals and marked for use with ranges
shall be used.