Diagnosis
Payload
{
"DIAG":{
"Timestamp":"<CPX:FBD_TIMESTAMP>",
"TimestampQuality":"<CPX:FBD_TIMESTAMP_QUALITY>",
"TemplateSelection":<TEMPLATE_SELECTION>,
"TemplateVersion":<TEMPLATE_VERSION>,
"ModuleNumber":<CPX:Mx_MODULE_NUMBER>,
"ChannelNumber":<CPX:Mx:Cx_CHANNEL_NUMBER>,
"ChannelType":"<CPX:Mx:Cx_CHANNEL_TYPE>",
"PNDeviceName":"<PN:PDN>",
"PNErrorCode":<CPX:Dx_DIAG_MESSAGE_ID_PROFINET>,
"MessageType":"<CPX:Dx_DIAG_MESSAGE_TYPE>",
"MessageStatus":"<CPX:Dx_DIAG_MESSAGE_STATUS>",
"MessageId":<CPX:Dx_DIAG_MESSAGE_ID_CPX>,
"MessageText":{
"en-US": "<CPX:Dx_DIAG_MESSAGE_TEXT>"
}
}
}
En el caso de diagnosis de módulos, se omiten las entradas para ChannelNumber y ChannelType.
9.8.2.7
Will
El Broker envía el telegrama cuando se interrumpe la conexión entre el nodo de bus y el Broker.
Topic
<TOPIC_PREFIX>/LASTWILL/<TEMPLATE_SELECTION>/<TEMPLATE_VERSION>
Payload
{
"LASTWILL":{
"TemplateSelection":<TEMPLATE_SELECTION>,
"TemplateVersion":<TEMPLATE_VERSION>,
"Publisher":"Offline"
}
}
36
Festo — CPX(-M)-FB33/34/35/43/44/45 — 2022-02f