Operations And Use; Routine, Scheduled And Extraordinary Maintenance - BSVILLAGE SP 3600 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
able collection of decommissioned equipment for re-
cycling, processing and environmentally compatible
disposal contributes in avoiding possible negative
effects on the environment and health and promote
the reuse and/or recycling of device materials. Illicit
product disposal by the user may be punishable by
current national laws.

6. Operations and use.

Do not use glue, sealant or other chemical prod-
ucts on threads or other product parts.
To disconnect the product from the power
mains, remove the power plug from the power
outlet without pulling on the power cord.
6.1. Operating description.
The product you purchase is designed to move wa-
ter in swimming pool. The rotor turns and transfers
water from the inlet to the outlet.
6.2. Application range.
The product cannot be used to purify water for hu-
man consumption.
The product cannot be used to purify liquids other
than fresh water.
The product was designed and constructed to
operate in above-ground fresh swimming pool,
located outdoors.
This powerful and reliable product can be used in
swimming pool, together with a filter, for water treat-
ment.
6.3. Use.
Cutting and/or altering the power cord is strictly
prohibited.
The product cannot be used to purify water for
human consumption.
The product cannot be used to purify liquids
other than fresh water.
The product cannot be used for medical/thera-
peutic purposes,
Dry operations are prohibited.
6.4. Operating limits and environmental limits.
• Maximum water temperature: 35 [°C].
• Minimum water temperature: 4 [°C].
6.5. Safety devices and signalling.
The product is equipped with a thermal protector.
Following any thermal protector operation, check
the causes that originated the product's malfunction.
For this purpose, please consult the "Troubleshoot-
ing" section.
The product shall go back to normal operating condi-
tions after it has cooled down (about 2÷3 hours) and/
or the caused that triggered the thermal protector
have been eliminated.
6.5.1. Power plug with residual current device (RCD,
when included).
Before turning on the product, always press the
RESET button. Check power plug with residu-
al current device operations by pressing the TEST
button (T).
replace the entire power plug with residual current
device with the power cord.
The power plug with residual current device does
not replace mandatory electrical safety components:
the electrical system must meet current internation-
al and/or national regulations. If necessary, contact
specialised technicians.
off a circuit in the event of fault. In order for it to work,
it must:
• always be in the vertical position,
• always be clean and free of dust or water,
• be connected to a perfectly efficient ground line,
• check residual current device operations before
6.5.2. Checking residual current device operations.
Plug the power plug with residual current device into
the power outlet:
1. press the RESET button to allow the product to
2. press the TEST (T) button to test residual current
with residual current device from the power outlet
and do not use the product. Contact a specialised
technician.
6.6. Hazards and risks.
The product is powered electrically, so maximum dili-
gence in its installation and maintenance is required,
in order to avoid danger. Please pay particular at-
tention to:
• the conditions of its power cord, which must not
• do not use the product without its pre-filter basket
• when using any type of stop valve make sure the
7. Routine, scheduled and extraordinary
Replace any damaged and/or worn components as
quickly as possible; use only original spare parts. For
this purpose, please consult the "Retail and spare
MANUALE_SP3600_BWT-A5 - Rev: 01/2020
Do not attempt to repair or open the power plug
with residual current device; in the event of fault,
The power plug with residual current device is an
additional electrical safety component able to cut
turning on the product (see below).
be turned on: the light turns red.
device operations: the light turns off and the
residual current device cuts off electrical power,
therefore the product cannot be turned on unless
the RESET button is pressed again.
If the residual current device triggers (turns off the
product) during product use, unplug the power plug
be damaged (Fig. 15);
(Fig. 19, # 1), when present, otherwise the prod-
uct may jam or be irreparably damaged;
line is completely open as the product must never
run with valves closed.
maintenance.
Before beginning any work, remember to unplug
the electrical plug from the electrical socket.
Do not lubricate and/or use detergents and/or
chemical products to clean the product.
All extraordinary maintenance (replacement of
supply cord, etc.) must be carried out by spe-
cialised technicians.
EN
21

Publicidad

Tabla de contenido
loading

Tabla de contenido