Dispensing the material

Refer to figures {G} and {H} on page 2:
1 . Press the trigger (7). Dispensing starts and the red dispense volume indicator (3)
moves forward. When the trigger (7) is released, dispensing stops.
2 . The dispensed volume flow-rate can be controlled with the pressure regulation
valve (8).

Removing the cartridge

Refer to figure {I} on page 2:
1 . Release the trigger (7) and press the retract button (10) until the plungers have
moved to the rear stop.
2 . Using the cartridge ejector button (5), press the cartridge out of the cartridge
holder and remove the cartridge upwards.
Dispose of the cartridge and mixer in accordance with the adhesive /
sealant manufacturer's instructions.

Removing and replacing cartridge holder and plunger discs

1 . Disconnect dispenser from compressed air supply.
2 . Squeeze sides of cartridge holder (6) and remove from top of the dispenser.
3 . Remove and replace plunger discs (2) using 4 mm hex key. Smaller plunger disk is
installed on the lower rod closest to handle (9).
4 . Install new cartridge holder (6) from the top of the dispenser until click. Cartridge
ejector button (5) should be closest to cartridge guide (1).
5 . Re-connect compressed air supply.