Measuring Process - Bosch GLM 100-25 C Professional Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
32 | English
The selected setting remains saved after you switch off the measuring tool.
For larger distances (approx. > 5 m), a target marking is additionally shown for marking
the measuring point.
For more information, you can access the online operating instructions at
www.bosch-pt.com/manuals

Measuring Process

Once switched on, the measuring tool is in the length measurement function.
Once the measuring tool has been switched on, the rear edge of the measuring tool is se-
lected as the reference level for measurement. You can change the reference level. (see
"Selecting the Reference Level", page 33)
Apply the measuring tool to the point at which you want to start the measurement (e.g.
wall).
Press the 
button to start the measurement.
Once the measurement process is complete, the laser beam will switch off. For a further
measurement, repeat this process.
Measured values or end results can be added or subtracted.
With a switched-on permanent laser beam and in the continuous measurement function,
the measurement begins immediately after the first press of the
The switched-on permanent laser beam is not switched off after the measurement Per-
manent Laser Beam.
For more information, you can access the online operating instructions at
www.bosch-pt.com/manuals
The measuring tool must not be moved during a measurement. Therefore, place the
measuring tool, as far as this is possible, against or on a firm stop or supporting sur-
face.
The reception lens (20), the laser beam output (21) and the camera (22) must not
be covered during the measuring process.
1 609 92A 7CC | (11.02.2022)
 button.
Bosch Power Tools

Publicidad

Tabla de contenido
loading

Tabla de contenido