Mounting
Very heavy product; hood handling and installation must be carried out by at least two persons.
Before beginning installation:
•
Check that the product purchased is of a suitable size for the chosen installation area.
•
•
Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets with screws (*), guarantees (*), etc.),
eventually removing them and keeping them.
•
If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall/ceiling.
for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.
•
In addition check whether near the installation area of the hood (in the area accessible also with the hood mounted) an electric socket
is available and it is possible to connect a fumes discharge device to the outside (only suction version).
•
Carry out all the masonry work necessary (e.g. installation of an electric socket and/or a hole for the passage of the discharge tube).
of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Do not
tile, grout or silicone this appliance to the wall. Surface mounting only.
OPERATION
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for
5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
WHI653S1XGB, WHI953S1XGB, WHI653S1XGW, WHI953S1XGW
T1
T2
SL1
To select the functions of the hood press on the symbol. Function will be activated when symbol will be released.
T1. Standby mode (the control panel off – all functions disabled) / ON (control panel switched on)
Note: After about a minute of inactivity (suction and lights), the hood will automatically switch to standby.
T2. ON/OFF lights
- with the lights on, touch the LED strip SL1
Note: the light turns on at the last set intensity before its switching off.
T3. ON/OFF Automatic operation "AdaptTech".
The hood automatically sets the suction speed (power) 2 to increase if the environmental conditions detected by the hood sensor
require it.
If there are no variations in the environmental conditions, after 10 minutes (if the hood is already in suction speed (power) 1), the hood
turns off.
Note:
paragraph).
Note: During automatic operation, if the user acts on the other functions that adjust the speed, auto ventilation function is switched off.
T4. ON/OFF Motor
- with the motor running, touch the led strip SL2
er).
Note: the motor starts running at the last suction speed (power) set before switching off.
T5. ON/OFF Intensive suction speed (power) "POWER BOOST" (timed)
Note: After 5 minutes of operation the hood returns to its previous state.
T6. ON/OFF intensive suction speed (power) "POWER BOOST x 2" (timed)
Note: After 5 minutes of operation, the hood goes back to the previous status.
T7. ON/OFF operation mode „ReFresh".
Every 50 minutes of inactivity, the suction speed (power 1 is turned on for 10 minutes.
T8. ON/OFF Timer of the suction speed (power).
Note: this function is available for the speeds that can be selected with button T4.
Press once or repeatedly to choose the delayed switch off time that you want to set (10-20-30 minutes)
T3
T4
SL2
„Setting of the parameters for Automatic Operation" (see corresponding
T5
T6
T7
T8
T9
-
EN
21