3. Setup

AC Power

AC Plug

Power Linking

F4 User Manual, Rev. 2
Each F4 has an auto-ranging power supply that works with an input voltage range of
100–240 VAC, 50/60 Hz. To determine the power requirements for each
F4, refer to the label affixed to the product. You can also refer to the
Specifications
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation.
For more information, you may download Sizing Circuit Breakers from the Chauvet
website: www.chauvetprofessional.com.
· Always connect this product to a protected circuit with an appropriate
electrical ground to avoid the risk of electrocution or fire.
· To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by
unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Each F4 comes with a power linking cord to connect power between panels and a power
input cord.
This cable has a Neutrik® powerCON® connector to connect to the F4 and an Edison
plug for power input. Use the table below as a reference to wire a new plug.
Connection
AC Live
AC Neutral
AC Ground
All F4 panels support power linking. Refer to the following table for specifications on
each panel.
Voltage
@ 120 V, 60 Hz
@ 208 V, 60 Hz
@ 230 V, 50 Hz
Please refer to all applicable local codes and regulations for the proper installation
of this product.
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
Screw Color
Brown
Yellow or Brass
Blue
Silver
Green