of installation. So for the hydraulic plant contact an authorized technician. Always
utilise the new hose supplied for connection to the water supply. Old hoses must
not be utilised.
•
On installation, the qualified electrician must fit a circuit breaker switch as fore-
seen by the safety norms in force that has a contact open distance that permits the
complete disconnection under conditions of overload category III.
For Australia, the above must be done according to the AS / NZS 3000 installation
standard.
•
In case of installation in kitchens, connect the equipotential conductor to the ter-
minal on the machine indicated by the symbol .
•
There are some basic rules for the use of any electrical appliance. In particular:
•
Never touch the unit with wet hands or feet;
•
Never use the unit with bare feet;
•
Never use extension cords in areas equipped with baths or showers;
•
Never pull on the power supply cord to unplug the unit;
•
Never leave the unit exposed to atmospheric agents (rain, direct sunlight, etc..);
•
Never let children, unauthorized personnel or anyone who has not read this
manual operate the unit.
•
The qualified electrician must also check that the section of the installation's ca-
bles is large enough for the absorbed power of the appliance.
•
Never use adapters, multiple jacks or extension cords. When such items prove ab-
solutely necessary, call in a qualified electrician.
•
To prevent dangerous overheating, it is advisable to fully extend the power supply
cord.
•
Never block the intake and/or heat dissipation grills.
•
The user must never replace the unit's power supply cord. If this cord is damaged,
turn off the unit and have it replaced by a professionally qualified technician.
•
Should it be necessary to replace the power cord, this replacement operation
must only be performed by an authorized service centre or by the manufacturer.
•
The device needs to be supplied with water that is suitable for human consump-
tion and compliant with the regulations in force in the place of installation. The
installation engineer needs confirmation from the owner/manager of the system
that the water complies with the requirements and standards stated above.
•
For machines connected to the mains water supply, the minimum pressure must
be 2 bar and the maximum pressure for correct machine operation must not ex-
ceed 4 bar.
•
The manufacturer cannot be held responsible for
any damages incurred if the system is not grounded.
For electrical safety, this machine requires a ground
system. Contact a technically certified electrician
who must check that the line electrical capacity is
adequate for the maximum capacity indicated on
the unit label.
13