Quick THG 1012 Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TECHNICAL DATA - INSTALLATION
GB
MODEL
MOTOR POWER
Motor supply voltage
Maximum pull
Maximum working load
Working load
Current absorption @ working load (1)
Maximum chain speed (2)
Maximum chain speed @ working load (2)
Ø Drum
Motor cable size (3)
Protection circuit breaker (4)
Deck thickness (5)
Weight
(1) After an initial period of use.
(2) Measurements taken with internal drum diameter.
(3) Minimum allowable value for a total length L<20m. Determine the cable size according to the length of the wiring.
(4) With switches designed for direct currents (DC) and delayed-action (thermal-magnetic or hydraulic-magnetic).
(5) On request, shafts and studs can be supplied for greater deck thicknesses.
Models' dimensions on page 34
INSTALLATION
BEFORE USING THE CAPSTAN READ THESE INSTRUCTIONS CAREFULLY.
IF IN DOUBT, CONTACT YOUR NEAREST "QUICK
WARNING:
the Quick
capstans are designed to weigh engineered for recovery tender.
®
Do not use the equipment for other purposes.
Quick
shall not be held responsible for damage to equipment and/or personal injury, caused by a faulty use of the equip-
®
ment.
The capstan is not designed for the loads that might occur in extreme weather conditions (storms).
Always deactivate the capstan when not in use.
For improved safety we recommend installing at least two anchor capstan controls in case one is accidentally damaged.
We recommend the use of the Quick
The contactor unit must be installed in a point protected from accidental water contact.
THE PACKAGE CONTAINS:
ditions of warranty.
TOOLS REQUIRED FOR INSTALLATION:
hexagonal wrenche: 6 mm.
"QUICK
"ACCESSORIES RECOMMENDED:
®
hand helds R/C (mod. HRC1002) - Foot switch (mod. 900) - Hydraulic-magnetic circuit breaker - Radio control RRC (mod. R02,
PO2, H02).
F
Quick
®
reserves the right to introduce changes to the equipment and the contents of this manual without prior notice.
In case of discordance or errors in translation between the translated version and the original text in the Italian language, reference will be made to the Italian or English text.
10
12 V
750 Kg (1653,5 lb)
300 Kg (661,4 lb)
70 A
6,2 m/min
(20,3 ft/min)
4,2 m/min
(13,8 ft/min)
40 A
®
hydraulic-magnetic switch as the motor safety switch.
®
Capstan - Contactor unit - Bolts and screws (for assembly) - Drill template - User's manual - Con-
drill and drill bit: Ø 11 mm (23/64"); fork or polygonal key 17 mm (43/64");
strap-roller with spring catch - Windlass control board (mod. 800) - Watertight
THG 1000
1000 W
24 V
1700 Kg (3747,8 lb)
800 Kg (1763,7 lb)
350 Kg (771,6 lb)
40 A
6,0 m/min
(19,7 ft/min)
4,8 m/min
(15,7 ft/min)
60 (2" 23/64)
35 mm
40 A
max 50 mm (1" 31/32)
18,9 kg (41,7 lb)
" DEALER.
THG 1500
1500 W
12 V
2000 Kg (4409,2 lb)
1000 Kg (2204,6 lb)
1200 Kg (2645,6 lb)
400 Kg (881,8 lb)
500 Kg (1102,3 lb)
108 A
6,0 m/min
(21,6 ft/min)
5,5 m/min
(18,0 ft/min)
(AWG 2)
2
60 A
20,2 kg (44,5 lb)
THG 1000/1500W - REV001A
24 V
66 A
8,0 m/min
(26,2 ft/min)
6,8 m/min
(22,3 ft/min)
40 A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Thg 1024Thg 1512Thg 1524

Tabla de contenido