STEINEL Studioline IS 2180-2 Instrucciones De Montaje página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
All manuals and user guides at all-guides.com
Installation/Wall mounting
Suppy cable
Surface wiring with wall mount
14
Concealed wiring
Surface wiring
Mains supply lead
Service lead
Note: The internal-corner
wall mount may be used for
mounting the sensor to the
wall. The cables can be
conveniently routed down
the surface of the wall
behind the unit and fed
through the cable entry.
The site of installation
should be at least 50 cm
from a light because heat
radiated from it may trigger
the sensor unintentionally
To obtain the specified
ranges of 5/12 m, the sen-
sor should be installed at a
height of approx. 2 m.
Installation procedure:
1. Detach front cover
,
2. Release clip
and flip
up lower half of housing,
3. Mark drill holes, 4. Drill
the holes, insert wall plugs
(6 mm dia.), 5. Break open
cable entry for surface or
concealed wiring.
6. Feed through mains
supply and service cable
and connect to terminals.
Use sealing plugs for
surface wiring.
a) Connect mains supply
lead
The mains supply leads is
a 2 to 3-core cable:
L = phase conductor
N
= neutral conductor
PE = protective-earth
conductor
If you are in any doubt, you
must identify the cables
using a voltage tester; once
you have done so, discon-
nect the power supply
again. Connect the phase
(L) and neutral conductor
(N) to the clamp-type ter-
minal. Connect the protect-
ive earth conductor to the
earth terminal ( ).
A power ON/OFF switch
may of course be installed
in the power supply lead.
Alternatively, you may use
a normally closed contact
pushbutton to activate the
sensor manually for the
duration of the time setting.

Publicidad

Tabla de contenido
loading

Tabla de contenido