5. Elements
5.1 Display (Fig. 1)
A 1: CO
indication
2
A 2: CO
history of the last 24 hours
2
A 3: Time
A 4: Temperature
A 5: Humidity
5.2 Buttons (Fig. 1)
B 1: MODE button
B 2: + button
5.3 Housing (Fig. 2+3)
C 1: Micro USB port
C 2: Mounting holes
6. Getting started
• Insert the supplied USB cable with the micro USB plug into the provided opening on the device. Connect
the device via the USB cable only to a suitable USB power source.
20
16:57 Uhr
Seite 11
AIRCO
NTROL COACH – CO
Monitor
2
2
• "Auto" is displayed shortly after a successful connection, then "- - - -"" The backlight turns on.
• The black bars disappear one by one.
• The device is ready for use.
• The actual measurements will appear on the display: CO
• The clock must be set to the current time in setting mode.
7. Settings
7.1 Selection of the multi-function display illumination
• The device has a multi-function display illumination in different colours. Depending on the setting, the
illumination colour is used to evaluate and interpret the current CO
• You can select your respective setting by pressing the MODE button.
• Wait some seconds until the display returns to normal mode to confirm the setting.
• The following four settings are available:
7.1.1 „Auto" (default)
In this mode, the display colour changes automatically in smooth transitions between the 3 colour
shades, depending on the current reading of the CO
Green:
Optimal air quality:
The CO
Yellow:
Medium air quality:
The CO
Red:
Poor air quality:
The CO
concentration, temperature, humidity.
2
measured values.
2
levels.
2
concentration is below 800 ppm.
2
concentration is between 800 ppm and 1400 ppm.
2
concentration is over 1400 ppm.
2
21