TFA_No. 31.5009_Anleitung
06.11.2018
AIRCO
NTROL COACH – CO
Monitor
2
2
CO
2
Measuring range
0 ...9999 ppm
Resolution
1 ppm
Accuracy
±7 % or ±100 ppm at 0...3000 ppm (whichever is greater)
±10 % at > 3000 ppm
Update interval
10 seconds
Warm-up time
approx. 10 seconds
Method
Non-Dispersive-Infrared Technology (NDIR)
Temperature
Measuring range
0 °C ... 50 °C
Resolution
0.1°C
Accuracy
± 1.0°C
Humidity
Measuring range
1% to 95% rH
Resolution
1% RH
Accuracy
±3 % rH (at 35...75 % rH)
26
16:57 Uhr
Seite 14
AIRCO
NTROL COACH – CO
Monitor
2
2
Operating temperature
0 °C ... 50 °C
Storage range
-20 °C ... 60 °C
Dimensions
105 x 32 x 55 mm
Weight
86 g (device only)
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the
time of going to print and may change without prior notice. The latest technical data and information about this product
can be found in our homepage by simply entering the product number in the search box.
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
11/18