Positioning The Ceiling Floor Unit; Installation Location; Accessing The Hanger - Baxi RZGNK35 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para RZGNK35:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
5 Installation
5.9

Positioning the ceiling floor unit

5.9.1

Installation location

Fig.190
Floor installation
500
Fig.191
Ceiling installation
20
3000
500
5.9.2

Accessing the hanger

Fig.192
1
3
164
When choosing the installation location, take into account the minimum
space requirements as described in the figures.
500
Select a suitable position in order to achieve a uniform air temperature
in the place of installation.
Make sure that the indoor unit is far enough from the food preparation
equipment to ensure that products are not attracted into the ceiling floor
unit
MW-6070072-01
500
MW-6070074-01
1. Slide the suction grid fixing knobs backwards to open the inlet grid.
2. Hold the knob at the back of the intet grid and pull the suction grid
forward to remove.
3. Unscrew in the bottom cover as shown. Remove the end cap by
pulling up.
2
7798731 - v01 - 18112021

Publicidad

Tabla de contenido
loading

Tabla de contenido