5 Installation
5.11.3

Connecting the units

Fig.205
Single phase models (2 cases)
MW-6070153-1
Fig.206
Three-phase models
172
A
B
230V~
50Hz
L
N
A
B
1
2
3
1
2
3
Caution
Use a suitable cable: power supply cables of parts of appliances
for outdoor use shall not be lighter than polychloroprene sheathed
flexible cable (design 60245 IEC 57).
A
B
X3 X4
B
A
X3 X4
1. Connect the cables to the appropriate terminals, as shown in the
figure.
Important
To avoid electric shock, make sure that the length of the
conductors between the traction arrester device and the terminal
blocks is such that the active conductors are put under tension
before the earth conductor.
Important
Correctly screw the cable clamps. Adjust the length of the cables
accordingly.
230V~
50Hz
L
N
230V~
50Hz
L
N
MW-6070152-1