3.8.6 Reset

If Reset is selected and confirmed, all the submenu value will be set to default.

3.9 Communication

Enter this menu to define external communication methods and to set printing parameters.
Data may be output to either a printer or PC.
Factory default settings are shown in bold.

3.9.1 RS232/2nd RS232 Configuration

Communication
Configuration
nd
RS232/2
RS232
Print Setup
3.9.1.1 Baud Rate
Set the baud rate (bits per second).
300
600
1200
2400
4800
9600
19200
3.9.1.2 Parity
Set the data bits and parity.
Options(bold is default)
300, 600, 1200, 2400, 4800, 9600, 19200,
Baud Rate
38400, 57600
Parity
7 Even, 7 Odd, 7 None, 8 None
Stop Bit
1 bit, 2 bit
Handshake
None, Xon/Xoff, Hardware
Alt Print CMD
'a' ~ 'z', 'A' ~ 'Z', P
Alt Tare CMD
'a' ~ 'z', 'A' ~ 'Z', T
Alt Zero CMD
'a' ~ 'z', 'A' ~ 'Z', Z
Reset
No/Yes
Demand
Stable Only
Auto On Stable
Mode
Auto On Accept
Assignment
Interval
Time
MT-Continuous
OH-Continuous
SICS
Reference Balance
Select
Simple, Custom 1, Custom 2, Custom 3,
Template
Custom 4, Custom 5
Print Cal Data
OFF, On
Edit Template
Field 1~ Field 50
Edit String
String 1~ String 20
Reset
Defender 5000 Indicators
Off, On (LFT Force On)
Load, Load and Zero
1~50000