Novoferm tormatic TAD MS 400V Manual De Instrucciones Y De Montaje página 37

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
Error
State
F20
Door responds only to
dead man's control
for closing
F21
Brief operational in-
terruption
F22
Hydraulic motor
switches off
F23
No response
F24
No response to start
command
F25
No response
F26
No response
F27
Drive blocked
F28
No response to start
command
F29
Motor rotates in incor-
rect direction.
F30
Door only runs in
dead man mode for
closing
F31
Door neither opens
nor closes
F32
Door neither opens
nor closes
F33
Door stops during the
opening process
F34
Door neither opens
nor closes
F35
Door neither opens
nor closes
F40
Extended control
does not respond
F41
Extended control
does not respond
F43
Extended control
does not respond
F45
RadioBand, wireless
closing edge
F46
RadioBand, wireless
closing edge
Diagnosed cause
Testing of photoelectric sensor
has failed. Check photoelectric
sensor.
Door movement exceeded time
value detected (90 sec). Check
door for ease of motion or block-
age. Check end positions.
Runtime limitation of motor pump,
faulty operation or defective but-
ton.
Electronic door lock EDL100 is
not responding. Check wiring.
Locking bolt is jammed, check
locking bolt for ease of motion.
Do not apply oil or grease to door
locking.
No connection to the DES. Check
motor connection cable and DES.
Internal test or membrane keypad
erroneous. Exchange membrane
keypad or control.
Internal test external button /
switch failed.
Check door mechanics / check
phases, motor connection cable.
Voltage supply error. Check
mains connection. Check peri-
pherals for short circuit.
Mains phases have been inver-
ted. Correct or re-adjust.
Return from pulsed operation to
dead man mode. Check closing
edge safety device and photo-
electric sensor.
Button actuated. Continuous
pulse pending. Check external
control devices (J1).
Spring fracture detection has
tripped. Check springs, replace, if
necessary. When the springs
have been replaced, the
door end position must be re-ad-
justed.
Opening force limitation has
tripped. Door can only be closed
in dead man mode. Eliminate
sluggishness or blockage of the
door. Check springs. Eliminate
the cause of the excessive force,
then open and close the door.
Duty cycle exceeded. Wait and let
motor cool down.
Speed monitor has tripped.
Check DU setting.
24 V failed. Check connections
on extended control.
Error occurred during self-testing.
Replace extended control.
No connection.
Module is not available, attach.
Replace battery.
Error
State
F71
Erroneous wicket
door contact. Door
neither opens nor
closes
F72
Door neither opens
nor closes
F73
Door neither opens
nor closes. Testing of
input J4.1/2 failed
F74
Door neither opens
nor closes. Testing of
input J4.3/4 failed
F75
Door neither opens
nor closes. Output
voltage J4 erroneous
F76
Door neither opens
nor closes. Invalid
sensors J4.1/2 detec-
ted
F77
Door neither opens
nor closes. Invalid
sensors J4.3/4 detec-
ted
F78
Drive blocks in end
position CLOSE
L
The access to the
menu was inhibited
by the authorized
specialist dealer.
Lo
Control has been in-
hibited.
U
The access to the
menu was unlocked
by the authorized
specialist dealer.
If the safety circuit is
interrupted, the warn-
ing indicator is illu-
minated, see
troubleshooting.
The warning indicator
flashes upon switch-
ing the main switch
on and off.
TAD MS 400V / 230V
Diagnosed cause
Check contact resistances. Check
assembly of wicket door, open
and close wicket door, check as-
sembly.
Short circuit detected in the safety
circuit wicket door contact / slack
rope switch J4.1/2. Check cables
for short circuit, eliminate short
circuit.
Switch control on and off. If ne-
cessary, replace control.
Switch control on and off. If ne-
cessary, replace control.
Switch control on and off. Check
closing edge safety device, door
connection box for short circuit.
Check terminal assignment.
Check resistors. Check sensors.
Check resistors. Check sensors.
Check spring tension, check door
mechanics, check CLOSE end
position.
Contact specialist dealer. Menu
can only be unlocked by means
of the service tool.
Contact specialist dealer. Menu
can only be unlocked by means
of the service tool.
The restart lock is active. Press
the
 button or RETURN.
EN - 35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tad ms 230vHad ms 400vHad ms 230v

Tabla de contenido