There are two power supply plugs on the back of the Minibar.
- Connect the "POWER" plug to the socket in the room specifically for the Minibar (socket not
connected to the energy saving system).
- Connect the "SIGNAL" plug to any socket connected to the energy saving system (Energy
saver).
NOTE: The K ECOSMART PV BLACK Minibar operates in STANDARD/TIMER mode where the
"SIGNAL" plug is not connected. Standard mode refers to operation not relative to identification
of the Guest in the room and operation which is regulated by the temperature selected by the
Client using the switch described above.
ATTENTION!
If the POWER and SIGNAL cables are connected in reverse, the fridge will operate whilst the
guest is in the room and will switch itself off when the guest leaves the room.
To confirm that the connection is correct, check that the light illuminates when opening the
Minibar door subsequent to checking that:
1) the energy saving system (Energy saver) is not functioning and that the smart card has not
been inserted
2) the Minibar is on (the temperature switch at the front of the Minibar must not be in position
"0").
In the instance that the light does not illuminate, invert the connection of the two power cables.