4.4 ERROR CODES
E01
E01
REVERSE POLARITY
Connect the charger according to "CoNNECT THE CABLES"
E02
OVER VOLTAgE
Batter y voltage to high for the chosen charging program, check battery voltage.
E03
TIME OUT STEP 1: DESULPhATION
Restart the charger. if charging is still being interrupted the battery is seriously sulphated and may need to be
replaced.
E04
TIME OUT STEP 2: SOFT START
Restart the charger. if charging is still being interrupted the battery can not accept charge and may need to be
replaced.
E05
TIME OUT STEP 5: ANALYSE
Restart the charger. if charging is still being interrupted the battery can not keep charge and may need to be
replaced.
E06
bATTERY OVERhEATED
The battery is too hot to charge. The battery is damaged and may need to be replaced.
E07
LOW bATTERY VOLTAgE IN SUPPLY PROgRAM
Battery voltage too low or too large consumers connected. Check if 12V battery connected in 24V battery set-
ting or disconnect large consumers.
E08
hIgh CURRENT IN SUPPLY PROgRAM
Check if clamps are short circuited or connected reversed polarity.
E99
OVER VOLTAgE PROTECTION
if battery voltage is below 17V the ERRoR lamp is lit when 24V setting has been selected.
Alt 1.
Press START/PAuSE button to charge with 12V setting. To set the parameters for customized
charging proceed with "CHARGiNG" step 5 to 8
Alt 2.
Press iNCREASE or DECREASE button to change to 24V setting. Press START/PAuSE button to
resume. To set the parameters for customized charging proceed with "CHARGiNG" step 5 to 8.
25 25