6. CONNECT ThE CAbLES
if the battery clamps are incorrectly connected, the reverse polarity protection will ensure that the battery and charger
are not damaged.
1. Connect the battery cable, including the temperature sensor, to the charger
2. Connect the mains cable to the charger
3. Connect the red clamp to the battery´s positive pole.
4. Connect the black clamp to the vehicle chassis remote from the fuel pipe and the battery.
5. Connect the charger to the wall socket
6. Disconnect the charger from the wall socket before disconnecting the battery
7. Disconnect the black clamp before the red clamp
6
5
6
2
1
50ºC
-20ºC
3
1
4
7
batteries and electronics will be damaged if 12V batteries are charged in 24V-setting.
27