STEP 6 RECOND
Choose the Ca/Ca program to add the Recond step to the charging process. During the Recond step voltage increases to
create controlled gasing in the battery. Gasing mixes the battery acid and gives back energy to the battery.
STEP 7 FLOAT
maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and gives a pulse when
necessary to keep the battery fully charged.
8. MOUNTINg
When permanently mounting the charger, mount the charger on a firm surface. Fix the charger with screws in the four
holes. use screws intended for the surface. Allow space around the charger to not interfere with air cooling.
4
150mm
50mm
150mm
50mm
29